Page Repositioning The Secondary Backplane Connector Installing the i server in a large Meridian 1 system Repositioning the secondary backplane connector Introduction The secondary backplane DS30X connector on the i server connects the server to the second slot on the shelf, thereby providing access to the voice channels provided by that slot. Page 51 November Secondary backplane connector description The secondary backplane connector is attached to the backplane edge of the i server.

It consists of the following items: connector screws pin connector with four pins Two pairs of screw holes are provided for connecting the secondary backplane connector to the i server stiffening cage. A pair of needle-nosed pliers can also be helpful for removing the pin connector. To prepare the i server for installation in a Meridian 1 switch 1 Remove the secondary backplane pin connector. Page 53 November See the following diagram: 5 Replace the pin connector so the pins protrude through both connectors.

Ensure that the connectors are correctly aligned as shown in the diagram below. Page 54 Installing the i server in a large Meridian 1 system Standard 1. Page 55 November 6 Gently press the pin connector into the socket until it is fully seated.

You can install the i server in slots 0 through Ensure that both slots have electrical backplane connectivity. To position the i server on the switch shelf 1 Ensure that no cables are connected to the slots in which you are installing the i server.

Page Removing The Backplane Tip And Ring Cables Installing the i server in a large Meridian 1 system Removing the backplane tip and ring cables Introduction You must remove the Meridian 1 backplane tip and ring cables that are associated with the slots occupied by the i server so that you can install the following cables: NTRH backplane tip and ring cable The NTRH cable offers more network throughput than the cable This cable offers more network throughput than the cable you just removed from the Meridian 1.

Page 66 Installing the i server in a large Meridian 1 system The connector on the intermediate SCSI cable that attaches to the i server faceplate is a low-profile right-angle connector.

This allows the cable to be attached with the Meridian 1 cabinet cover on. The tape drive is the last device. Page 70 Installing the i server in a large Meridian 1 system 7 Replace the protective plate. Page 73 November See the following diagram: 2 Ensure that no cables are connected to the slots in which you are installing the i server.

Note: When you open the top lock latch, it breaks the yellow backplane warning label, if the label has not been removed. Ensure that the i server is positioned correctly between the slots.

Note: When correctly inserted in the Option 11C Mini, the top of the i server is on the left. Continue with installing the cables. If you want to use a connection scenario that is not described in this guide, ensure that you use appropriate cabling for each device.

Below the card cage, temporarily remove the hardware that secures cable connections to the Option 11C. Temporarily remove any cabling that may interfere with the installation of the intermediate SCSI cable bracket assembly. Note: When routing the SCSI cable through the card cage, ensure the second cable ferrite is placed halfway through the opening.

You will connect it later to the i server faceplate. If you want to use a connection scenario that is not described in this guide, ensure that you use appropriate cabling for each SCSI device. Page 89 November See the following diagram: Note: After you remove the bracket, refasten the screws in their original locations inside the cabinet.

Page 91 November See the following diagram: Note: Ensure the fiber routing spool and bracket are correctly aligned before fastening them in place. See the diagram in step 4. Page Installing the i server in the Succession system Media Gateway and Media Gateway Expansion 3 Physical slot Media Gateway Expansion Back panel connectors The following table describes the connectors that are located on the back of each Media Gateway and Media Gateway Expansion, and how they relate to CallPilot: Connector Four pin amphenol connectors that interface with Page Installing the i server in the Succession system Note: Except for the back panel connectors, the Media Gateway Expansion is similar in external appearance to the Media Gateway.

Succession software For the i server, the Succession system must be running Succession Release 3. Page November a. Insert the screwdriver approximately 2 cm 0. At the same time, gently pull the bezel away from the chassis approximately 2 cm [0. Page Installing the i server in the Succession system 2 Remove the inside front cover plate as follows: a. Use a screwdriver to loosen each screw on the top of the inside front cover plate by three turns.

Apply pressure and slide the inside front cover plate upward to the left until the screw holes are aligned with the screw heads. Before you begin Determine which pair of consecutive slots are to contain the i server. Before you begin 1.

Page Installing the i server in the Succession system Note: After you remove the bracket, refasten the screws in their original locations inside the cabinet. Page November 5 Replace the inside front cover plate. To replace the inside front cover plate The following diagram provides an overview of how to install the inside front cover plate Page November 1 Insert the bottom tabs of the front cover plate inside the bottom rail.

When the blue LEDs inside these units are lit, they are very bright. Page Installing the i server in the Succession system c. A maximum of You must connect a monitor, keyboard, and mouse to run the Configuration Wizard or to install the operating system on the i server as part of a recovery process. Four specially-designed card slots are available for the MPC All are located on the i server faceplate. The SCSI connection is the only permanent faceplate connection.

A lowprofile right-angle connector on the SCSI cable allows the cable to be attached with the cabinet covers on. For more information about how the i server and SCSI device connections are achieved, see:. If you are connecting more than one SCSI device to the server such as a tape drive , you must daisy chain those devices. You must power off the server to connect or disconnect the drive.

An external SCSI tape drive is used to back up and restore data. Note: The tape drive is not hot-pluggable. An external modem provides remote access to the i server. Without the extension cable, the monitor connector partially blocks the mouse connector. This section provides a high-level overview of the requirements and procedure for installing the i server. Ensure that proper power and grounding are available for all the power outlets serving the CallPilot server and its associated peripherals.

Power for these devices must be wired and fused independently of all other receptacles and referenced to the same ground as the PBX system. A qualified electrician must implement the single-point ground reference as required between the power outlets of the CallPilot server and the power outlets of the switch.

Provide a sufficient number of properly grounded power outlets or power bars for all equipment. The following checklist identifies the steps required to install the i server and peripheral devices. If this requirement is not met, power transients can cause personal injury and hardware failure. Server Configuration guide for your switch and server.

Before proceeding with the installation, visually inspect the i server for any damage that might have occurred during shipping. Ensure also that the items in the following checklists are secure:. The information in this section will help you plan your i server installation. Note: The i server cannot be installed in slots 0 or 4, because these slots are dedicated to other cards. For more information about cards and slots, refer to the Succession Planning and Installation Guide.

This connection corresponds to the left slot when viewing the front of the Meridian 1 switch. This connection corresponds to the right slot when viewing the front of the Meridian 1 switch. If the LAN is to be networked with the i server, you need a network specialist to ensure proper configuration. Install the i server in the Meridian 1 switch or Succession system.

For instructions, see one of the following:. The secondary backplane DS30X connector on the i server connects the server to the second slot on the shelf, thereby providing access to the voice channels provided by that slot.

The i server is shipped ready for installation into an Option 11C switch. Before you install the i server in a larger Meridian 1 switch for example, Option 51C , you must move the secondary backplane DS30X connector to the correct position. This cable offers more network throughput than the cable that is already installed on the Meridian 1. You require two cables.

There is an approximate difference of 2 mm 0. As a result, you must install the secondary backplane DS30X connector on the i server in the correct position before a successful connection with the switch backplane can be established. Welcome to ManualMachine. We have sent a verification link to to complete your registration.

Log In Sign Up. Forgot password? Enter your email address and check your inbox. Please check your email for further instructions. Enter a new password. Nortel Networks. Nortel Networks i User Manual Download for 1.

Standard 1. All Rights Reserved. Publication history November Standard 1. October Standard 1. September Standard 1. July Standard 1. April Standard 1. November Standard 1.

May Standard 1. Publication history Standard 1. Task List Standard 1. How to get help 13 About the i server Contents Standard 1. C h a p t e r 1 How to get help This section explains how to get help for Nortel products and services. How to get help Standard 1. C h a p t e r 2 About the i server In this chapter i server description 16 Network connectivity 24 Peripheral connectivity About the i server Standard 1. Primary components The i server motherboard houses the interfaces needed: to communicate with the Meridian 1 switch or Succession system to facilitate data communications on Ethernet networks.

November About the i server Two Ethernet controllers on the i server motherboard provide Ethernet capability. Keyboard connector Mouse connector Monitor connector Faceplate. Heat sink Hard drive power cable Hard drive data cable Secondary backplane connector pin Secondary backplane connector 3. November About the i server Faceplate The following diagram shows the i server faceplate.

Lock latches Lock latches at the top and bottom of the faceplate secure the server to the backplane of the Meridian 1 switch or the backplane of the Succession Media Gateway or Media Gateway Expansion.

Infrared port For future use. Monitor connector The monitor connector is a standard, high-density, pin female connector.

It is safe to remove the card. Press the button to eject the card from its slot. You can install up to four MPCs on the i server. The i is shipped with two MPC-8 cards installed. All slots are faceplate- accessible. Hexadecimal HEX The four-digit LED-based display provides feedback display on the current status of the server, including fault conditions.

Press the button latches to lock or unlock a cable from the connector. When they are lit, they indicate that the interfaces are properly attached to their respective hubs. When the LEDs are blinking, there is network activity. Reset button The reset hardware was designed for Windows NT and does not function properly in Windows Do not use this button. Sample network setup: Meridian 1 switch The following diagram shows how the i server is integrated into your network with the following Meridian 1 switches: large systems, such as Option 51C Option 11C Option 11C Mini.

This connection allows the exchange of call control information between the server and the Meridian 1 switch or Succession system. The modem allows administrators and technical support personnel to administer the i server from a remote location. Click Here to join Tek-Tips and talk with other members! Already a Member? Join your peers on the Internet's largest technical computer professional community. It's easy to join and it's free. Register now while it's still free! Already a member?

Close this window and log in. Join Us Close. Join Tek-Tips Forums! Join Us! By joining you are opting in to receive e-mail. Promoting, selling, recruiting, coursework and thesis posting is forbidden. Students Click Here. Our Callpilot i lost its hard drive a couple days ago and I'm having a heck of a time getting it back online. It's in an Option 11c in slot 10 and when I'm going through the config wizard and get to the part of the switch setup where you assign SCNs, the first two of the four boxes you use to select TNs are greyed out.